The air system of the concrete mixing station is one of the main systems of the concrete mixing station. If it fails, the whole concrete mixing plant may be paralyzed. Therefore, the routine maintenance of the gas system must be carried out on schedule, and there must be no negligence. Here we will explain the problems in this area, hoping to help everyone in their daily use.
First, the air compressor should be placed horizontally, fixed, and well ventilated.
Second, can not withstand the wind and rain, nor can it be exposed to the sun.
3. Adjust the upper and lower limits of the air pressure automatic switch. If the pressure is too low, it will cause the cylinder to slow down. If the pressure is too high, it will be detrimental to the gas system seal.
Fourth, check the oil level of the lubricant, keep the oil level between the upper and lower lines of the oil dipstick, when the oil level is close to the lower line, add new oil.
Fifth, check whether the tension of the conveyor belt is appropriate. When pressing the belt with your fingers, the belt sinks about 10mm. It is advisable to replace the entire group when replacing the conveyor belt to maintain the same tension.
What we mentioned above, you must strictly observe the daily use and maintenance of concrete mixing plant. Good use and maintenance habits can not only improve the working efficiency of the equipment, but also extend its service life, thereby bringing good economic benefits to your business.